​RS3080CJ

Drop-in equivalent of RS 3080 CJ
Water Cooled Triode For Industrial RF Heating

Power Triode Tube Valve

Output Power: 130 kW (CW mode)

Anode voltage: 14 kV

Anode dissipation: 60 kW max.

Frequency: 100 MHz max

Warranty: 12 months irrespective of number of hours in operation

Condition: Brand New

Price: Please call +91-9815309603 or email: sales@pilanielectron.com

Manufactured in India, in a world-class facility equipped with high quality machinery, materials and components sourced from reputed suppliers in America, Europe and Japan.

Category: Product ID: 7611

Description

The RS3080CJ is a RF power triode designed for dielectric heating applications. This tube uses a coaxial design and metal-ceramic technology. This triode may be operated in CW or pulse modes. For operation in pulse mode, the parameters depend on each equipment characteristics. Contact us for specific information. The RS3080CJ is a water cooled triode.

Electrical characteristics of RS3080CJ

Cathode Filament thoriated tungsten

Filament voltage (+ 5 %, – 10 %) 11 V

Filament current 205 A

Surge current (maximum) 615 A

Capacitances:

Grid to Anode: 46 pF

Grid to Cathode: 106 pF

Cathode to Anode (see note 2): 3 pF

Amplification factor: 19

Transconductance (Va: 4 kV, Ia: 3 A): 60 mA/V approx.

Mechanical characteristics of RS3080CJ

Operating position: vertical, anode up or down

Weight: 8 kg (17.6 lbs) approx.

Dimensions: see outline drawing

Maximum ratings of RS3080CJ

Frequency: 30 MHz

Anode voltage: 14 kV

Control grid voltage: -1.5 kV

Control grid current:

On load, CW: 2.3 A

Off load, CW: 2.6 A

Peak cathode current, CW: 85 A

Anode dissipation: 60 kW

Grid dissipation: 1.25 kW

Grid resistance (at blocked tube): 8 KΩ

Typical Operation of RS3080CJ (Class C RF oscillator for industrial applications)
Frequency <30 MHz
Anode voltage 12 kV
Control grid bias -1055 V
RF Control grid voltage 1555 V
Anode current 12.7 A
Control grid current 2.2 A
Anode input power 151.9 kW
Anode output power 106 kW
Anode dissipation 35 kW
Control grid dissipation 942 W
Grid resistance 485 Ω
Feedback ratio 14.8 %
Oscillator efficiency 74.9 %

Operations at higher frequencies available upon request

Cooling of RS3080CJ

Anode cooling: Water

Cooling water flow and pressure gradient: see cooling curves

Cooling water inlet pressure: 5 bar max

Water inlet temperature: 35 °C max

Temperature at any point on tube envelope: 220 °C max

Air flow on tube terminal side: 3 m³/min