​RS3080CL

Drop-in equivalent of RS 3080 CL
Forced Air Cooled Triode For Industrial RF Heating

Power Triode Tube Valve

Output Power: 120 kW (CW mode)

Anode voltage: 14 kV

Anode dissipation: 45 kW

Frequency: 100 MHz max

Warranty: 12 months irrespective of number of hours in operation

Condition: Brand New

Price: Please call +91-9815309603 or email: sales@pilanielectron.com

Manufactured in India, in a world-class facility equipped with high quality machinery, materials and components sourced from reputed suppliers in America, Europe and Japan.

Category: Product ID: 7614

Description

​The RS3080CL is a RF power triode designed for industrial heating applications. This tube uses a coaxial design and metal-ceramic technology. This triode is designed to operate in CW modes. For operation in pulse mode, the parameters depend on each equipment characteristics. Contact us for specific information. The RS3080CL is a forced-air cooled triode.

Electrical characteristics of RS3080CL

Cathode Filament: thoriated tungsten

Filament voltage (+5%, -10%): 11 V

Filament current: 205 A

Surge current (maximum): 615 A

Capacitances:

Grid to Anode: 46 pF

Grid to Cathode: 106 pF

Cathode to Anode (see note 2): 3 pF

Amplification factor: 19

Transconductance (Va: 4 kV, Ia: 3 A): 60 mA/V approx.

Mechanical characteristics of RS3080CL

Operating position: vertical, anode up or down

Weight: 18.5 kg (41 lbs) approx.

Dimensions: see outline drawing

Maximum ratings of RS3080CL

Frequency: 30 MHz

Anode voltage: 14 kV

Control grid voltage: -1.5 kV

Cathode current:

On load, CW: 2.3 A

Off load, CW: 2.6 A

Peak cathode current, CW: 85 A

Anode dissipation: 45 kW

Grid dissipation: 1.25 kW

Grid resistance (at blocked tube): 8 KΩ

Typical Operation  of RS3080CL (Class C RF oscillator for industrial applications)
Frequency <30 MHz
Anode voltage 12 kV
Control grid bias -1055 V
RF Control grid voltage 1555 V
Anode current 12.7 A
Control grid current 2.2 A
Anode input power 151.9 kW
Anode output power 106 kW
Anode dissipation 35 kW
Control grid dissipation 942 W
Grid resistance 485 Ω
Feedback ratio 14.8 %
Oscillator efficiency 74.9 %

Operations at higher frequencies available upon request

Cooling of RS3080CL

Anode cooling: forced air

Cooling water flow and pressure gradient: see cooling curves

Inlet air temperature: 25 °C typical

Temperature at any point on tube envelope: 220 °C max.

Cooling Curves RS 3080 CL
(For air flow from electrode terminal side)

Pa : anode dissipation   Δp : pressure drop

q : air flow rate  Tout : air outlet temperature

Picture

Constant Current Characteristics of RS 3080 CL

Picture

Outline Drawing (in mm) of RS 3080 CL

Picture

Cart0