3CW10000H3

Drop-in equivalent of 3CW10000H3
Water Cooled Triode For Industrial RF Heating

Power Triode Tube Valve

Output Power: 18 kW (CW mode)

Anode voltage: 10 kV max

Anode dissipation: 10 kW max

Frequency: 90 MHz max

Warranty: 12 months irrespective of number of hours in operation

Condition: Brand New

Price: Please call +91-9815309603 or email: sales@pilanielectron.com

Manufactured in India, in a world-class facility equipped with high quality machinery, materials and components sourced from reputed suppliers in America, Europe and Japan.

Category: Product ID: 7617

Description

3CW100000H3 is a water-cooled, ceramic-metal power triode with a robust mesh filament, for use in industrial radio-frequency heating

Electrical Characteristics of 3CW100000H3

Filament: Thoriated tungsten

Filament voltage (see note 1): 7.5 V

Filament current: 75 A

Surge Filament current (peak) (see note 2): 375 A

Filament cold resistance: 11.8 mΩ

Peak usable cathode current: 20 A

Amplification factor: 20

Inter – electrode capacitances:

Grid to anode: 27 pF

Grid to filament: 54 pF

Anode to filament: 1.8 pF

Mechanical Characteristics of 3CW100000H3

Connections: Filament leads and grid contact flanges

Operating position: vertical, either way up

Maximum operating temperature: 250 O C

Maximum dimensions: see outline

Net weight: 4 kg (8.8 pounds) approx

Accessories

Water coupling, supplied with 3CW100000H3: CWPA323A

Thermal fuse available for 3CW100000H3: PA85E

Cathode connector: WPA830

For frequencies above 2MHz, CWPA830 should be used in conjunction with a strip connection to provide a low inductance cathode return.

Cooling

Anode of 3CW100000H3 is cooled by circulating water through the removable anode water jacket. The table below lists the minimum water flow requirement for adequate anode cooling at various anode dissipation levels. In all cases, the outlet water temperature must not exceed 70 ⁰C nor should inlet water pressure exceed 60 psi. This table is based upon 20 ⁰C temperature rise.

Additional forced-air cooling of the tube base is also required to maintain ceramic-to-metal seal temperature below the 250 ⁰C maximum. Approximately 50 ft3/min of cooling air directed into the base structure will generally satisfy requirements.

Minimum Water Cooling Requirements of 3CW100000H3
Anode Dissipation (kW) Water Flow (l/min) Pressure Drop (psi)
5 10 2.2
7.5 12 2.3
10 13 2.5
15 15 3.0

The values given allow for maximum filament and grid dissipation in addition to the anode dissipation shown.

Radio Frequency Oscillator For Industrial Service
(Class C Conditions, One Tube)
Maximum Ratings (Absolute Values)
Frequency 90 MHz max
Anode voltage d.c 10 kV max
Anode current d.c. (see note 3) 3.0 A max
Anode input power 25 kW max
Anode dissipation 5 kW max
Grid voltage d.c –1000 V max
Grid current d.c (see note 4) 0.5 A max
Grid dissipation 150 W max
Cathode current d.c 4.0 A max
Typical Operating Conditions of 3CW100000H3
Frequency 30 30 MHz
Anode voltage d.c 7.0 9.0 kV
Anode current d.c 2.65 2.52 A
Anode dissipation 4.1 4.1 kW
Grid voltage d.c -700 -900 V
Grid resistor 3650 4900 Ω
Grid current d.c 192 184 mA
Grid dissipation 44 42 W
Drive power 179 208 W
Anode input power 18.6 22.7 kW
Anode output power 14.5 18.6 kW
Output power less drive 14.3 18.4
NOTES: