3CW20000H3

Drop-in equivalent of 3CW20000H3
Water Cooled Triode For Industrial RF Heating

Power Triode Tube Valve

Output Power: 28 kW (CW mode)

Anode voltage: 10 kV max

Anode dissipation: 20 kW max

Frequency: 90 MHz max

Warranty: 12 months irrespective of number of hours in operation

Condition: Brand New

Price: Please call +91-9815309603 or email: sales@pilanielectron.com

Manufactured in India, in a world-class facility equipped with high quality machinery, materials and components sourced from reputed suppliers in America, Europe and Japan.

Category: Product ID: 7620

Description

3CW20000H3 is a water-cooled, ceramic-metal power triode with a robust mesh filament, for use in industrial radio-frequency heating

Electrical Characteristics 3CW20000H3
Filament Thoriated tungsten
Filament voltage (see note 1) 7.5 V
Filament current 100 A
Surge Filament current (peak) (see note 2) 500 A
Filament cold resistance 9.7 mΩ
Peak usable cathode current 26 A
Amplification factor (Va = 2.3 kV, la = 1.0 A) 20
Mutual conductance (Va = 2.5 kV, la = 1.3 A) 31 mA/V
Grid to anode 39 pF
Grid to filament 54 pF
Anode to filament 2.0 pF
Mechanical Characteristics of 3CW20000H3

Connections: Filament leads and grid contact flange

Operating position: vertical, either way up

Maximum operating temperature: 250 degree Centigrade

Maximum dimensions: See outline drawings

Net weight: 4 kg (8.8 pounds) approx

Accessories of 3CW20000H3

Water coupling, supplied with 3CW20000H3: CWPA323A

Thermal fuse available for 3CW20000H3: PA85E

Cathode connector: CWPA830

For frequencies above 2MHz, CWPA830 should be used in conjunction with a strip connection to provide a low inductance cathode return.

Cooling

Anode of 3CW20000H3 is cooled by circulating water through the removable anode water jacket. The table below lists the minimum water flow requirement for adequate anode cooling at various anode dissipation levels. In all cases, the outlet water temperature must not exceed 70 ⁰C nor should inlet water pressure exceed 60 psi. This table is based upon 20 ⁰C temperature rise.
Additional forced-air cooling of the tube base is also required to maintain ceramic-to-metal seal temperature below the 250 ⁰C maximum. Approximately 50 ft3/min of cooling air directed into the base structure will generally satisfy requirements.

Minimum Water Cooling Requirements of 3CW20000H3
Anode Dissipation (kW) Water Flow (l/min) Pressure Drop (psi)
10 12 2.5
15 13 3.0
20 15 3.5
25 18 4.0

The values given allow for maximum filament and grid dissipation in addition to anode dissipation shown.

Radio Frequency Oscillator For Industrial Service
(Class C Conditions, One Tube)
Maximum Ratings (Absolute Values)
Frequency 90 MHz max
Anode voltage d.c. 10 kV max
Anode current d.c. (see note 3) 4.0 A max
Anode input power 40 kW max
Anode dissipation 10 kW max
Grid voltage d.c. –1000 V max
Grid current d.c. (See note 4) 0.6 A max
Grid dissipation 250 W max
Cathode current d.c. 5.0 A max
Typical Operating Conditions of 3CW20000H3
Frequency 30 30 MHz
Anode voltage d.c. 7.0 9.0 kV
Anode current d.c. 4.0 4.0 A
Anode dissipation 9 7 kW
Grid voltage d.c. -670 -930 V
Grid resistor 2450 2160 Ω
Grid current d.c. 275 430 mA
Grid dissipation 94 168 W
Drive power 260 570 W
Anode input power 28 36 kW
Anode output power 19 29 kW
Output power less drive 18.7 28.4 kW
NOTES: