RS3026CL

Drop-in equivalent of RS 3026 CL
Forced Air Cooled Triode For Industrial RF Heating

Power Triode Tube Valve

Output Power 32 kW (CW mode)

Anode voltage 12 kV

Anode dissipation 15 kW max.

Frequency 120 MHz max

Warranty 12 months irrespective of number of hours in operation

Condition Brand New

Price Please call +91-9815309603 or email: sales@pilanielectron.com

Manufactured in India, in a world-class facility equipped with high quality machinery, materials and components sourced from reputed suppliers in America, Europe and Japan.

Category: Product ID: 7596

Description

The RS3026CL is a RF power triode designed for industrial applications. This tube uses a coaxial design and metal-ceramic technology. This triode may be operated in CW or pulse modes. For operation in pulse mode, the parameters depend on each equipment characteristics. Contact us for specific information. The RS3026CL is a water cooled triode.

Electrical characteristics of RS3026CL

Cathode Filament thoriated tungsten

Filament voltage (+5%, -10%) 7 V

Filament current 115 A

Surge current (maximum) 345 A

Capacitances:

Grid to Anode 26 pF

Grid to Cathode 59 pF

Cathode to Anode (1) 1.5 pF

Amplification factor 20 Approx.

Transconductance (Va: 3 kV, Ia: 2 A) 33 mA/V approx.

Note (1) Measured with a 30 cm diameter shielding plate in the grid terminal plane.

Mechanical characteristics of RS3026CL

Operating position vertical, anode up or down

Weight 11 kg (24.2 lbs) approx.

Dimensions see outline drawing

Maximum ratings of RS3026CL

Frequency 120 MHz

Anode voltage:

Up to 40 MHz 12 kV

From 40 to 80 MHz 11 kV

From 80 to 120 MHz 9 kV

Control grid voltage -1.5 kV

Control grid current (F < 40 MHz)

At full load, CW 1.1 A

At no load, CW 1.4 A

Peak cathode current, CW 30 A

Anode dissipation 15 kW

Grid dissipation:

Up to 40 MHz 550 W

From 40 to 80 MHz 450 W

From 80 to 120 MHz 350 W

Grid resistance (at blocked tube) 15 KΩ

Cooling of RS3026CJ

Anode cooling forced air

Cooling water flow and pressure gradient see cooling curves

Inlet air temperature 25 °C typical

Temperature at any point on tube envelope 220 °C maximum

Typical Operation of RS3026CL (Class C RF oscillator for industrial applications)
Frequency <40 <40 MHz
Anode voltage 10 8 kV
Control grid bias -800 -650 V
RF control grid voltage 1.2 1.05 kV
Anode current 4.1 4.2 A
Control Grid current 700 760 mA
Anode input power 41 33.6 kW
Anode output power 32 25 kW
Anode dissipation 8.2 7.8 kW
Control Grid dissipation 240 260 W
Grid resistance 1.15 0.86 kΩ
Feedback ratio 13.5 15 %
Oscillator efficiency 78 74.5 %
Cart0